Residential energy storage
20.48kWh/25.6kWh Three-Phase Stacked All-in-One Unit
Stackable three-phase inverter-and-battery unit, 10 kW or 15 kW, with seamless backup.
Models
- HJ-H20-H10 (k-2)
- HJ-H25-H15 (k-3)
Request a quote
Contact our sales team for pricing, lead times and configuration options.
Contact salesOverview
A three-phase home storage system that stacks hybrid inverter and battery modules into one slim column. It runs grid-tied or off-grid and switches to backup without interruption.
Key features
- Four-leg inverter handles 100% three-phase imbalance
- Up to 1.7× DC oversizing and reduced high-temperature derating
- PV input 180–900 V, battery range 180–700 V
- Modular, stackable design that fits modern interiors
Typical applications
Three-phase homes with PV, heat pumps or EV charging.
Technical specifications
| Parameter | HJ-H20-H10 (k-2) | HJ-H25-H15 (k-3) |
|---|---|---|
| Photovoltaic Parameters | ||
| Max Input Power [W] | 17000 | 25500 |
| Max Input Voltage [V] | 1000 | |
| Operating Voltage Range/Rated Voltage [V] | 180~900/610 | |
| Max Input Current [A] | 18/18 | 36/36 |
| Max Short Circuit Current [A] | 20/20 | 40/40 |
| MPPT Count | 2 | |
| Number of Strings per MPPT | 1/1 | |
| AC Parameters (Grid Side) | ||
| Rated Output Power (W) | 10000 | 15000 |
| Max Apparent Output Power (VA) | 11000 | 16500 |
| Max Input Power (W) | 18000 | 30000 |
| Rated Voltage (Vac) | 380/400V, 3L/N/PE | |
| Rated Frequency (Hz) | 50/60 | |
| Max Output Current (A) | 16 | 24 |
| Max Three-Phase Imbalance Output Current [A] | 22 | 33 |
| Grid Bypass Current [A] | 35 | 50 |
| Power Factor Range | ~1 (0.8 leading, 0.8 lagging, adjustable) | |
| Total Harmonic Distortion (@Rated Power) (%) | <3 | |
| AC Parameters (Off-Grid Side) | ||
| Rated Output Power (W) | 10000 | 15000 |
| Max Apparent Output Power (VA) | 11000 | 16500 |
| Rated Output Voltage (Vac) | 380/400V, 3L/N/PE | |
| Rated Output Frequency (Hz) | 50/60 | |
| Max Three-Phase Imbalance Output Current [A] | 22 | 33 |
| Max Output Single-Phase Apparent Power [VA] | 5000 | 7500 |
| Peak Output Apparent Power (VA) (60s) | 12000 | 18000 |
| Peak Output Apparent Power (VA) (10s) | 15000 | 22500 |
| Grid/Off-Grid Switching Time (ms) | <10 | |
| AC Parameters (Diesel Generator Side) | ||
| Rated Voltage (Vac) | 380/400V, 3L/N/PE | |
| Rated Frequency (Hz) | 50/60 | |
| Rated Input Apparent Power (VA) | 10000 | 15000 |
| Battery Parameters | ||
| Operating Voltage Range (V) | 204.8 | 256 |
| Rated Charge/Discharge Current (A) | 50/50 | |
| Max Charge/Discharge Current (A) | 50/50 | |
| Number of Batteries | 4 | 5 |
| Single Battery Capacity (kWh) | 5.12 | |
| Rated Capacity (kWh) | 20.48 | 25.6 |
| Usable Capacity (kWh) | 18.43 | 23.04 |
| System Efficiency | ||
| Standard Ambient Temperature System Efficiency [%] | 88 | |
| Basic Parameters | ||
| Operating Temperature Range (°C) | -25~60 (>45 de-rating) | |
| Operating Altitude (m) | <4000 | |
| Protection Rating | IP65 | |
| Relative Humidity Range (%) | 0~95, no condensation | |
| Dimensions (W*H*D) (mm) | 510*447*1323 | 510*447*1463 |
| Certification Standards | IEC62109-1/-2 | |
| Certification Standards | ||
| Safety Standards | EN61000-6-1/-3, IEC61000 | |
| EMC Standards | AS4777.2:2020, NRS097-2-1:2017, EN 50549-1 for Czech, VDE-AR-N 4105:2018, EN50549-1:2019+AC:2, G98 G99, OVE-R25, EN50549-1:2019 for Poland A&B | |