Residential energy storage
5.3kWh-15.9kWh Single-Phase Stacked All-in-One System
Single-phase stacked all-in-one system, 5.3–15.9 kWh, with UPS-grade backup and VPP support.
Models
- HJ-H05-H05 (k-7)
- HJ-H10-H05 (k-8)
- HJ-H15-H05 (k-9)
Request a quote
Contact our sales team for pricing, lead times and configuration options.
Contact salesOverview
A single-phase stacked system offered in three capacities from 5.3 kWh to 15.9 kWh. Its EMS optimises household energy automatically, and it is ready for grid services such as FCAS and virtual power plants.
Key features
- UPS-grade redundancy protects backup loads
- Up to 10 kW PV input, 100–550 V MPPT range
- Built-in EMS for automatic optimisation
- Grid-service ready (FCAS, VPP)
Typical applications
Single-phase homes seeking backup and lower energy bills.
Technical specifications
| Parameter | HJ-H05-H05 (k-7) | HJ-H10-H05 (k-8) | HJ-H15-H05 (k-9) |
|---|---|---|---|
| Battery Parameters | |||
| Battery Type | Li-ion / Lead-acid | ||
| Rated Battery Voltage [V] | 96 | ||
| Battery Voltage Range [V] | 80-450 | 80-450 | 80-467.2 |
| Maximum Charging Current [A] | 60 | ||
| Maximum Discharge Current [A] | 60 | ||
| Photovoltaic Input | |||
| Maximum Photovoltaic Input Power [kW] | 10 | ||
| Maximum Photovoltaic Input Voltage [V] | 580 | ||
| MPPT Tracking Range [V] | 100-550 | ||
| Start-up Voltage [V] | 100 | ||
| Maximum Input Current [A] | 15/15 | ||
| Maximum Short-circuit Current [A] | 18.75/18.75 | 18.75/18.75 | 22.5/22.5 |
| MPPT Trackers | 2 | ||
| MPPT Tracker Configuration | 1/1/1 | ||
| Grid Parameters | |||
| Rated Output Power [kVA] | 5/4.6 (DE) | 5/4.6 (DE) | 6 |
| Maximum Output Current [A] | 22.7 | 22.7 | 27.2/26 |
| Maximum Apparent Output Power [kVA] | 5/4.6 (DE) | 5/4.6 (DE) | 6 |
| Maximum Input Power [kVA] | 10 | 10 | 11.5 |
| Rated Grid Voltage [Vac] | 230 | 230 | 220/230 |
| Grid Voltage Range [Vac] | 180-270 | ||
| Rated Grid Frequency [Hz] | 50/60 | ||
| Power Factor | -0.8 ~ +0.8 | ||
| THDi | <3% | ||
| Backup Ports | |||
| Peak Backup Power [kVA] | 10 | 10 | 11.5 |
| Rated Backup Power [kVA] | 5 | 5 | 6 |
| Rated Backup Voltage [Vac] | 230 | 230 | 220/230 |
| Rated Backup Frequency [Hz] | 50/60 | ||
| Total Harmonic Distortion (Voltage) | <3% (Linear Load) / <5% (Non-linear Load) | ||
| DC Voltage | <100mV | ||
| Peak Ratio | 3:1 | ||
| Switching Time | <10ms | ||
| Efficiency | |||
| Maximum Efficiency | 97.30% | ||
| European Efficiency | 96.20% | ||
| Maximum Power Point Tracking Efficiency | 99.90% | ||
| Maximum Round-trip Efficiency | 90% | ||
| HMI & COMM. | |||
| Communication with BMS | CAN/RS-485 | ||
| Load Monitoring | Meter/CT/Backup box | ||
| External Communication | RS-485/WIFI/4G/Ethernet | ||
| User Interface | LED/LCD | ||
| Battery Parameters | |||
| Total Energy [kWh] | 5.3 | 10.6 | 15.9 |
| Battery Module | 102.4V 5.3kWh | ||
| Number of Modules | 1 | 2 | 3 |
| Battery Type (2) | LFP (LiFePO4) | ||
| Rated Voltage [V] | 102.4 | 204.8 | 307.2 |
| Operating Voltage [V] | 80-116.8 | 160-233.6 | 240-350.4 |
| Maximum Charge/Discharge Current [A] | 52 | ||
| Sustained Discharge Power [kW] | 5 | 10 | 15 |
| General Parameters | |||
| Dimensions (W×D×H) [mm] | 740*220*970 | 740*220*1305 | 740*220*1640 |
| Approximate Weight [kg] | 86 | 136 | 186 |
| Enclosure Protection Rating | IP65 | ||
| Operating Temperature | Charging Temperature: 0℃~50℃ / Discharging Temperature: 0℃~50℃ | ||
| Storage Temperature | 0℃~35℃ | ||
| Humidity | ≤95% | ||
| Altitude [m] | ≤3000 | ||
| Cycle Life | Inverter: 5 years / 10 years; Battery: 10+ years, 6000 cycles (90% DoD, 25℃) | ||
| Installation | Stacked, Floor-mounted Installation | ||
| Certification | |||
| Grid Safety Standards | VDE-AR-N4105:2018, G98, G99, C10/11:2021, NTS 631, RD647:2020, UNE 217002:2020, CEI0-21, VDE 0126-1-1, NRS 097-2-1, AS/NZS 4777.2:2020, EN 50549-1 | VDE-AR-N4105:2018, G98, G99, C10/11:2021, NTS 631, RD647:2020, UNE 217002:2020, CEI0-21, VDE 0126-1-1, NRS 097-2-1, AS/NZS 4777.2:2020, EN 50549-1 | CEI0-21, NRS 097, IEC 61727, IEC 62116, EREC G99 |
| Safety Standards | IEC/EN 62109-1&2, IEC/EN 62477-1:2012 | ||
| Electromagnetic Compatibility | IEC/EN 61000-6-1, IEC/EN 61000-6-2, IEC/EN 61000-6-3, IEC/EN 61000-6-4 | ||
| Battery | UN38.3, IEC62619 | ||